2013年11月5日 — RTI has units of (m/s)0.5. Source: Resolution A.800(19), Revised Guidelines for Approval of Sprinkler Syst...

Sprinkler rti unit

2013年11月5日 — RTI has units of (m/s)0.5. Source: Resolution A.800(19), Revised Guidelines for Approval of Sprinkler Systems Equivalent to that Referred to in ... ,The RTI can also be specified in imperial units, where 1 ft½s½ is equivalent to 0.55 m½s½. The sensitivity of a sprinkler can be negatively affected if the thermal ...

相關軟體 Deluge 資訊

Deluge
Deluge 是一個功能齊全的 BitTorrent 客戶端,用於 Linux,OS X,Unix 和 Windows。它在後端使用 libtorrent,並具有多個用戶界面,包括:GTK +,Web 和控制台。它的設計使用客戶端服務器模型和一個處理所有 bittorrent 活動的守護進程。 Deluge 守護進程能夠在無人機上運行,用戶界面可以從任何平台遠程連接.Deluge 功能豐富的插件集... Deluge 軟體介紹

Sprinkler rti unit 相關參考資料
Automatic Sprinkler Thermal Sensitivity - Viking Group Inc.

NFPA 13 section 3.6.1(a) (1) defines the response time for fast response sprinklers as having a thermal element with an RTI of 50. (meter- ...

https://www.vikinggroupinc.com

Definition of Response time index (RTI) - IADC Lexicon

2013年11月5日 — RTI has units of (m/s)0.5. Source: Resolution A.800(19), Revised Guidelines for Approval of Sprinkler Systems Equivalent to that Referred to in ...

https://www.iadclexicon.org

Fire sprinkler - Wikipedia

The RTI can also be specified in imperial units, where 1 ft½s½ is equivalent to 0.55 m½s½. The sensitivity of a sprinkler can be negatively affected if the thermal ...

https://en.wikipedia.org

ISO 6182-1:2004(en), Fire protection — Automatic sprinkler ...

Note 1 to entry: The conductivity factor is expressed in units of (m/s)0,5. 3.1.3. response time index. RTI. measure of sprinkler sensitivity mml_m1. where ...

https://www.iso.org

response time index of sprinklers - Department of Building ...

Response time index (RTI) is one of the properties of the sprinkler head itself. It is independent of the gas velocity but depends on the properties of the sprinkler ...

https://www.bse.polyu.edu.hk

Sprinkler Characteristics According to NFPA 13 - Fire ...

2019年9月6日 — (a) For RTI of 50 (meters-seconds)1∕2 or less, sprinkler is defined as ... of fire origin and that is listed for use in the protection of dwelling units.

https://www.fps-eg.com

Sprinkler heads - GW Sprinkler AS

The RTI unit is ms½ and is an indicator for the thermal sensitivity of the sprinkler. THERMAL RESPONSE. Sprinkler heads come with various types of thermal ...

https://www.gwsprinkler.com

Thermal Sensitivity Evaluation of Recessed, Flush and ... - iafss

covered directly by the RTI concept, primarily developed for sprinklers fully ... allowed times was taken as the temperature rating plus 3.5% (in units of OF), the.