Manchester system point A

由 A Mourya 著作 · 2021 · 被引用 6 次 — This study is a comparison between revised Manchester Point A and International C...

Manchester system point A

由 A Mourya 著作 · 2021 · 被引用 6 次 — This study is a comparison between revised Manchester Point A and International Commission on Radiation Units and measurements (ICRU) 89 report–recommended ... ,由 A Srivastava 著作 · 2014 · 被引用 27 次 — The strong point of Manchester system point A prescription was the constancy of dose rate at the point A, irrespective of the combination of tandems and ovoids ...

相關軟體 Iridium 資訊

Iridium
Iridium 瀏覽器基於 Chromium 代碼庫。所有修改都會增強用戶的隱私,確保使用最新,最安全的技術。防止部分查詢,關鍵字,指標自動傳輸到中心服務,並且只有在用戶批准的情況下才會發生。此外,我們所有的構建都是可重複的,而且修改是可審計的,使項目領先於其他安全的瀏覽器提供商. 選擇版本:Iridium 2017.11(32 位)Iridium 2017.11(64 位) Iridium 軟體介紹

Manchester system point A 相關參考資料
AN EVALUATION OF THE MANCHESTER SYSTEM OF ...

由 G SCHWARZ 著作 · 1969 · 被引用 32 次 — Point. A (Fig. I,. 1-F). Adequate dosage to the periphery of the tumor during ... Standard. Manchester system. patients with narrow vaults, bulky, barrel ...

https://www.ajronline.org

Brachytherapy

由 A Mourya 著作 · 2021 · 被引用 6 次 — This study is a comparison between revised Manchester Point A and International Commission on Radiation Units and measurements (ICRU) 89 report–recommended ...

https://www.sciencedirect.com

Brachytherapy in cancer cervix: Time to move ahead from ...

由 A Srivastava 著作 · 2014 · 被引用 27 次 — The strong point of Manchester system point A prescription was the constancy of dose rate at the point A, irrespective of the combination of tandems and ovo...

https://www.ncbi.nlm.nih.gov

Definitions and potential errors of Manchester point A and ...

According to the Manchester dosimetry system, A points were determined 2 cm above the upper surface of the ovoids, 2 cm away from the tandem, to the right and ...

https://www.researchgate.net

Dosimetric impact of point A definition on high-dose-rate ...

由 J Anderson 著作 · 2012 · 被引用 30 次 — Manchester point A: 2 cm superior to the tandem flange and 2 cm lateral from the center of tandem. This was the revised point A from 1953 [3].

https://www.ncbi.nlm.nih.gov

MANCHESTER SYSTEM FOR GYNECOLOGICAL ...

This concept of the statement of dosage to a single point, made this system as the most acceptable brachytherapy technique for the treatment of cervical cancer.

https://www.aapm.org

Point A or Point H in Prescribing High-Dose-Rate (HDR ...

The Manchester system is the most common system used in intracavitary brachytherapy for cervical carcinoma. Although some variations exist, it defines typically point A dose as the dose at 2 cm above ...

https://www.redjournal.org

Point A or Point H in Prescribing High-Dose-Rate (HDR) ...

由 TY Eng 著作 · 2007 · 被引用 5 次 — Although some variations exist, it defines typically point A dose as the dose at 2 cm above the external cervical os (flange) and 2 cm lateral to midline ( ...

https://www.redjournal.org

The Manchester System of Intracavitary Brachytherapy for ...

The system was designed to deliver a dose of 7000- 8000 mg-hrs of radium over a period of five days.in this system, almost an equal amount of radium was used in ...

https://www.aroiwb.org